On-site power generation for factory consumption, renewable energy, and CO₂ emissions reduction
Estimated annual generation: approximately 1.81 million kWh; expected to meet approximately 6.2% of the plant's annual electricity demand; estimated CO₂ emissions reduction: approximately 753 t-CO₂ per year
Tess Engineering delivered a solar power generation system for Hitachi Construction Machinery Co.,Ltd.'s Kasumigaura Plant. Tess Engineering is a consolidated subsidiary of the Company.
Head office: Taito-ku, Tokyo; Representative Executive Officer, President and COO: Senzaki Masafumi (先崎正文); Kasumigaura Plant location: Kasumigaura, Ibaraki Prefecture. No business description is provided.
Low-profile mounting system: Registered Trademark No. 6052650. Expiration date: Not disclosed
Kasumigaura, Ibaraki Prefecture (Hitachi Construction Machinery Co.,Ltd.'s Kasumigaura Plant)
In this announcement the company addresses none of Contract Value / Offering price / Impact on Business Performance.
Ministry of the Environment, “List of Emission Factors by Electricity Retailer (for Reiwa 8 submissions).” The alternative emission factor of 0.000416 t-CO₂/kWh for electricity retailers was used to calculate the CO₂ reduction.
| Item | Details |
|---|---|
| Names of Products / Services Covered | Solar power generation system |
| Counterparty | Hitachi Construction Machinery Co.,Ltd. |
| Counterparty overview | Head office: Taito-ku, Tokyo; Representative Executive Officer, President and COO: Senzaki Masafumi (先崎正文); Kasumigaura Plant location: Kasumigaura, Ibaraki Prefecture. No business description is provided. |
| Relationship with the Company | Tess Engineering delivered a solar power generation system for Hitachi Construction Machinery Co.,Ltd.'s Kasumigaura Plant. Tess Engineering is a consolidated subsidiary of the Company. |
| Launch date | February 2026 (delivery date; completed) |
| Applicable area | On-site power generation for factory consumption, renewable energy, and CO₂ emissions reduction |
| Registration number and expiry date | Low-profile mounting system: Registered Trademark No. 6052650. Expiration date: Not disclosed |
| Location | Kasumigaura, Ibaraki Prefecture (Hitachi Construction Machinery Co.,Ltd.'s Kasumigaura Plant) |
| Location scale | Generation capacity: 1,501.26 kW; 2,292 solar panels rated at 655 W each |
| Quantitative Effects | Estimated annual generation: approximately 1.81 million kWh; expected to meet approximately 6.2% of the plant's annual electricity demand; estimated CO₂ emissions reduction: approximately 753 t-CO₂ per year |
| Source | Ministry of the Environment, “List of Emission Factors by Electricity Retailer (for Reiwa 8 submissions).” The alternative emission factor of 0.000416 t-CO₂/kWh for electricity retailers was used to calculate the CO₂ reduction. |